Update - We have brought up the Equinix FR7 (FFM5) points of presence with RETN again, to distribute load any better.
Apr 07, 2024 - 12:21 UTC
Update - Our measures seem to be dealing with the situation any better. Attack is still running and hitting our points of presence, however load on the mitigation infrastructure decreased to a acceptable level. We'll be considering additional hardware upgrades beside of already planned ones.
Apr 06, 2024 - 18:00 UTC
Monitoring - We have been alerted by our monitoring about a huge DDoS attack causing congestion on the Interxion (Digitalrealty) FRA16 DDoS-Filters. Total attack size is over 600mpps with small packets congesting the mitigation infrastructure. We're currently looking into the issue and implementing mitigations.
Apr 06, 2024 - 17:42 UTC
Network Infrastructure Operational
90 days ago
99.98 % uptime
Today
Upstream BGP Sessions Operational
90 days ago
100.0 % uptime
Today
Cloud Storage Network Operational
90 days ago
100.0 % uptime
Today
DDoS-Protection Operational
90 days ago
100.0 % uptime
Today
Core Network Operational
90 days ago
99.94 % uptime
Today
Interconnection Operational
90 days ago
100.0 % uptime
Today
Public REST API Operational
90 days ago
100.0 % uptime
Today
Request Handler Operational
90 days ago
100.0 % uptime
Today
Scheduling Services Operational
90 days ago
100.0 % uptime
Today
Public Services Operational
90 days ago
100.0 % uptime
Today
Nameservers Operational
90 days ago
100.0 % uptime
Today
DNS Caches Operational
90 days ago
100.0 % uptime
Today
Corporate Websites Operational
90 days ago
100.0 % uptime
Today
my.aurologic.com Operational
90 days ago
100.0 % uptime
Today
mirror.aurologic.com ? Operational
90 days ago
100.0 % uptime
Today
Cloud Infrastructure Operational
90 days ago
100.0 % uptime
Today
FFM1 - Langen, Germany Operational
90 days ago
100.0 % uptime
Today
Dedicated Servers Operational
90 days ago
100.0 % uptime
Today
FFM1 - Langen, Germany Operational
90 days ago
100.0 % uptime
Today
FFM2 - Frankfurt, Germany Operational
90 days ago
100.0 % uptime
Today
FFM3 - Frankfurt, Germany Operational
90 days ago
100.0 % uptime
Today
EGH1 - Eygelshoven, Netherlands Operational
90 days ago
100.0 % uptime
Today
HEL1 - Helsinki, Finland Operational
90 days ago
100.0 % uptime
Today
Operational
Degraded Performance
Partial Outage
Major Outage
Maintenance
Major outage
Partial outage
No downtime recorded on this day.
No data exists for this day.
had a major outage.
had a partial outage.
Past Incidents
Apr 16, 2024

No incidents reported today.

Apr 15, 2024

No incidents reported.

Apr 14, 2024

No incidents reported.

Apr 13, 2024

No incidents reported.

Apr 12, 2024

No incidents reported.

Apr 11, 2024

No incidents reported.

Apr 10, 2024

No incidents reported.

Apr 9, 2024

No incidents reported.

Apr 8, 2024

No incidents reported.

Apr 7, 2024

Unresolved incident: Congestion on FFM3 DDoS-Filters.

Apr 6, 2024
Apr 5, 2024

No incidents reported.

Apr 4, 2024

No incidents reported.

Apr 3, 2024
Resolved - The issue has been resolved and a RFO will be released in the upcoming days.
Apr 3, 03:38 UTC
Update - It appears that 80% of the racks within the HEL1 region are supplied with connectivity, awaiting for the rest.
Apr 3, 02:53 UTC
Update - We observe connectivity restored for the first customers, namely colocation. The onsite personel of the datacenter operator is still rewiring the new equipment with the connections of the broken one.
Apr 3, 02:44 UTC
Update - Configuration has been restored, awaiting reconnection from the onsite personel of the datacenter operator.
Apr 3, 02:21 UTC
Update - Both devices are hardware dead at once, restoring firmware doesnt help. We suspect the flash might be broken and have died during the last commit. As the Finland location is quite distant to our office address and so to say spare-part storage, while it is quite unusual to store more than a redundant pair on-site, we're currently waiting for urgent hardware replacement. This is in progress and we're currently preparing the setup, expected ETA is 1-2 hours.

Connectivity will be in the first stage exclusively done over our Equinix FR7 (FFM5) points of presence, where we got transport connectivity from HEL1. Router configuration at FFM5 is currently being prepared. Please bear with us, we're doing our utmost to restore network connectivity within this pop.

Apr 3, 01:52 UTC
Update - We were finally able to gain serial console access. Investigation takes some time due to distance and the dependency on the datacenter operator. One of the switches, the previous primary one, appears to have a faulty hardware component hindering it from booting. The other one we're currently investigating.
Apr 3, 01:17 UTC
Update - It appears that one member of the routers is unable to boot anymore. We're currently investigating rescue access to stabilize the situation.
Apr 3, 00:00 UTC
Identified - We're currently facing a outage of the core routing stack in the Helsinki, Finland region. Following a previous outage of Elisa Oyj, we have turned back BGP-Sessions and the equipment went unresponsive while doing so. We're currently waiting for hands-on to carry out a power cycle.
Apr 2, 23:37 UTC
Apr 2, 2024